SIEMENS Hot Sale SITRANS LVL200 Process Instrumentation Level Measurement Point Level New & Original with very competitive price
- Product description
- Contact us
SIEMENS SITRANS LVL200 Process Instrumentation
Level Measurement Point Level New & Original
SITRANS LVL200 is a standard vibrating level switch for use in all liquid and slurry applications such as overflow, high, low,
and demand applications, as well as pump protection. For use in SIL-2 applications. SITRANS LVL200 is a level
switch designed for industrial use in all areas of process technology and can be used with liquids and slurries.
With a tuning fork insertion length of only 40 mm (1.57“), SITRANS LVL200 can be mounted in small pipes and applications with confined space.
The LVL200 can be used to measure products with a minimum density of >0.5 g/cm³ (0.018 lbs/in³).
The LVL200 can be used in difficult conditions including turbulence, air bubbles, foam generation, buildup, or strong external vibration.
SITRANS LVL200 continuously monitors faults via frequency evaluation, providing early detection of strong
corrosion or damage on the tuning fork, loss of vibration, or a line break to the piezo drive.
The tuning fork is piezoelectrically energized and vibrates at its mechanical resonance frequency of approx. 1200 Hz.
The vibration frequency changes when the tuning fork is covered by the medium.
This change is detected by the integrated oscillator and converted into a switching command.
The integrated electronics evaluate the level signal and output a switching signal, directly operating connected devices.
Key Applications: For use in liquids and slurries, for level measurement, overfill, and dry run protection.
Benefits
Proven vibrating level switch technology for liquids
Compact insertion length of 40 mm (1.57 inch) for confined space applications
Fault monitoring for corrosion, loss of vibration or line break to the piezo drive
Functional Safety (SIL 2). Device suitable for use in accordance with IEC 61508 and IEC 61511
Hygienic process connections
Suitable for API 2350
Optional remote test signal conditioner
Application
SITRANS LVL200 is a level switch designed for industrial use in all areas of process technology and can be used with liquids and slurries.
With a tuning fork insertion length of only 40 mm (1.57 inch), SITRANS LVL200 can be mounted in small pipes and applications with confined space.
The LVL200 can be used to measure products with a minimum density of > 0.5 g/cm³ (0.018 lb/in³).
The LVL200 can be used in difficult conditions including turbulence, air bubbles, foam generation, buildup, or external vibration.
SITRANS LVL200 continuously monitors faults via frequency evaluation, providing early detection of strong corrosion or damage on the tuning fork, loss of vibration, or a line break to the piezo drive.
The tuning fork is piezoelectrically energized and vibrates at its mechanical resonance frequency of approximately 1 200 Hz.
The vibration frequency changes when the tuning fork is covered by the medium. This change is detected by the integrated oscillator and converted into a switching command.
The integrated electronics evaluate the level signal and output a switching signal, directly operating connected devices.
The optional signal conditioner provides a remote test feature to ensure continuous product reliability.
Key Applications: for use in liquids and slurries, for level measurement, overfill, and dry run protection
Technical specifications
Mode of operation | |
Measuring principle | Vibrating point level switch |
Input | |
Measured variable | High and low and demand (via mode switch) |
Output | |
Output options |
|
Measuring accuracy | |
Repeatability | 0.1 mm (0.004 inch) |
Hysteresis | Approx. 2 mm (0.08 inch) with vertical installation |
Switching delay |
|
Frequency |
|
Rated operating conditions | |
Installation conditions | |
| Indoor/outdoor |
Ambient conditions | |
| -40 ... +70 °C (-40 ... +158 °F) |
| III |
| 2 |
Medium conditions | |
| |
| -50 ... +150 °C (-58 ... +302 °F) |
| -50 ... +250 °C (-58 ... +482 °F) |
| -50 ... +150 °C (-58 ... +302 °F) |
| -50 ... +250 °C (-58 ... +482 °F) |
| -196 … +450 °C (-321 … +842 °F) |
Pressure (vessel) |
Note: The process pressure is dependent on configuration, including process fitting, e.g. flange |
Density | 0.7 ... 2.5 g/cm³ (0.025 ... 0.09 lb/in³); Density optionally starts at 0.47 cm3(0.017 lb/in3) |
Design | |
Material | |
|
|
| 316L (1.4404 or 1.4435), Alloy C22 |
| 316L (1.4404 or 1.4435), Alloy C22 |
|
|
| 316L (1.4404 or 1.4435), 316L with Alloy C22, ECTFE, or PFA coating |
| Klingersil C-4400 |
Process connection | |
| G ¾" A, G 1" A |
| ¾" NPT, 1" NPT, 1½" NPT |
| DIN from DN 25, ASME from 1" |
| Bolting DN 40 PN 40, 1, 1½, 2, 2½" Tri-Clamp PN 10, conus DN 25 PN 40, Tuchenhagen Varivent DN 50 PN 10, SMS |
Degree of protection | Type 4X/NEMA 4X/IP66/IP67 |
Conduit entry |
|
Weight | |
| Approx. 0.8 ... 4 kg |
| Approx. 920 g/m |
Power supply | |
Supply voltage | |
| 20 ... 253 V AC, 50/60 Hz, |
| 20 ... 253 V AC, 50/60 Hz, 20 ... 253 V DC |
| |
Operating voltage (characteristics according to standard) for connection to an amplifier according to NAMUR | IEC 60947-5-6, approx. 8.2 V |