SIEMENS Hot Sale SITRANS LVS200 Process Instrumentation Level Measurement Point Level New & Original with very competitive price
- Product description
- Contact us
SIEMENS SITRANS LVS200 Process Instrumentation
Level Measurement Point Level New & Original
SITRANS LVS200 is a vibrating point level switch for high or low levels of bulk solids.
The standard LVS200 detects high, low or demand levels of dry bulk solids in bins, silos or hoppers.
The liquid/solid interface version can also detect settled solids within liquids or solids within confined spaces such as feed pipes.
It is designed to ignore liquids in order to detect the interface between a solid and a liquid.
A pipe extension version is available with either the standard or liquid/solid interface electronics and fork, separated by a customer supplied 1" pipe.
SITRANS LVS200 has an optional 4 to 20 mA output for monitoring buildup on the fork to determine
when preventative maintenance should be performed in sticky applications. The LVS200 has a compact design and can be top, side or angle mounted.
The vibrating fork design ensures the tines are kept clean. The unique design of the fork and crystal assembly
eliminates false high level readings even if tines become damaged.
A signal from the electronic circuit excites a crystal in the probe causing the fork to vibrate.
If the fork is covered by material, the change in vibration is detected by the electronic circuitry which causes the relay to change state after a one second delay.
When the fork is free from material pressure, full vibration resumes and the relay reverts to its normal condition.
Key Applications: dry bulk solids in bins, silos, hoppers or settled solids within liquids (interface version).
Benefits
High resistance to mechanical forces
Strong vibration resistance to high bulk material loads
Rotatable enclosure for convenient wiring
Suitable for low density material: standard version, 20 g/l (1.3 lb/ft3); liquid/solid interface version, 50 g/l (3 lb/ft3) and low density option min. 5 g/l (0.3 lb/ft3)
Customer desired extensions up to 20 000 mm (787 inch)
Optional detection of solids within liquid
Durable short fork option with 165 mm (6.5 inch) insertion length
Application
The standard LVS200 detects high, low, or demand levels of dry bulk solids in bins, silos, or hoppers.
The liquid/solid interface version can also detect settled solids within liquids or solids within confined spaces such as feed pipes.
It is designed to ignore liquids in order to detect the interface between a solid and a liquid.
A pipe extension version is available with either the standard or liquid/solid interface electronics and fork, separated by a customer supplied 1 inch pipe.
SITRANS LVS200 has an optional 4 to 20 mA output for monitoring buildup on the fork to determine
when preventative maintenance should be performed in sticky applications.
The LVS200 has a compact design and can be top, side or angle mounted.
The vibrating fork design ensures the tines are kept clean. The unique design of the fork and crystal assembly eliminates false high level readings even if tines become damaged.
A signal from the electronic circuit excites a crystal in the probe causing the fork to vibrate.
If the fork is covered by material, the change in vibration is detected by the electronic circuitry which causes the
relay to change state after a one second delay. When the fork is free from material pressure, full vibration resumes and the relay reverts to its normal condition.
Key Applications: dry bulk solids in bins, silos, hoppers or settled solids within liquids (interface version)
Technical specifications
Mode of operation | |
Measuring principle | Vibrating point level switch |
Input | |
Measured variable | High, low, and demand |
Measuring frequency | |
| 125 Hz |
| 350 Hz |
Output | |
PNP | Open collector: |
2-wire without contact | Load current:
Voltage drop on the electronic module: max. 7 V with closed electric circuit Cut-off current with open electric circuit: max. 5 mA |
Relays | |
| SPDT relay |
| DPDT relay |
Relay delay |
|
Signal delay |
|
Relay fail-safe | High or low, switch selectable |
Alarm output |
|
mA output | 8/16 mA or 4 ... 20 mA |
| 4 ... 20 mA ± 0.1 mA |
Sensitivity | High or low, switch selectable |