SIEMENS Hot Sale SITRANS LG Guided wave radar level measurement 100% New & Original with very competitive price and One year Warranty
- Product description
- Contact us
SIEMENS SITRANS LG Guided wave radar level measurement
100% New & Original with very competitive price
The SITRANS LG series are guided wave radar transmitters for level, level/interface, and volume measurement of liquids and solids.
It is unaffected by changes in process conditions, high temperatures and pressures, and steam.
The SITRANS LG series comes in four different models, depending on the applications, level of performance, and functionality required:
The Siemens SITRANS LG series are guided wave radar transmitters for level, level/interface, and volume measurement of liquids and solids.
The SITRANS LG product line can handle changes in process conditions, high temperatures and pressures, and steam.
Benefits
High accuracy to +/- 2 mm
Advanced Diagnostics available for high degree of safety
Simple menu driven display offers ease of setup
Large range of options offers reliability in most continuous level measurement applications
Ease of maintenance through module design and field replaceable and adjustable probe options
Perfect solution for wide range of applications from storage to interface with options for extreme pressure and temperature conditions
Universally applicable in liquids, interface, slurries and solids
Highly immune to buildup using auto learn function
Ability to measure in loss of echo situations with probe end tracking
Suitable for API 2350
Convenient access using USB and remote interface accessories
Application
The SITRANS LG series comes in four different models, depending on the applications, level of performance, and functionality required:
SITRANS LG240 offers configuration options for your hygienic and corrosive application requirements
SITRANS LG250 Highly flexible solution for liquid level and interface applications. Extremely versatile offering
solutions for storage, separation of materials or difficult ammonia applications
SITRANS LG260 Ideal for measuring level in medium range solids applications including; grains, plastics, and cement
SITRANS LG270 offers configuration options for extreme conditions including high temperature and high
pressure applications such as:harsh applications found in chemical, HPI and energy industries for example,
LPG gas tanks, steam boilers and distillation columns
Technical specifications
Mode of operation | |
Measuring principle | Guided wave radar measurement |
Measuring range | 300 ... 75 000 mm (11.81 ... 2 952.75 inch) |
Output | |
mA analog output with HART digital signal | 4 ... 20 mA/HART (SIL optional) |
Output range | |
| Current: minimum 3.8 mA, maximum 20.5 mA |
| ≤ 10 mA for 5 ms after switching on, ≤ 3.6 mA |
Diagnostic alarm | Failure signal current output (adjustable): last valid measured value, ≥ 21 mA, ≤ 3.6 mA |
Digital communication | HART Version 7 x and multidrop compatible |
Modbus | Modbus RTU, Modbus ASCII |
PROFIBUS PA | PROFIBUS PA profile 3.02 |
FOUNDATION Fieldbus | FOUNDATION Fieldbus protocol Physical layer according to IEC 61158-2 |
Performance | Process reference conditions according to DIN EN 61298-1 |
| < 500 ms |
| ≤ 3 s |
| The measurement error from the process conditions is in the specified pressure and temperature range of below 1 % |
Non-linearity | |
| |
| |
| See manual for more details |
Resolution and repeatability | Accuracy +/- 2 mm (0.08 inch) |
Accuracy | |
| +/- 2 mm (0.08 inch) |
| +/- 5 mm (0.197 inch) Note: Typical deviation, Interface measurement. See manual for full explanation. |
Rated operating conditions | |
Ambient temperature for enclosure | -40 ... +80 °C (-40 ... +176 °F) |
LCD readable temperature range | -40 ... +80 °C (-40 ... +176 °F) with display heated option |
Location | Indoor/outdoor |
Installation category | II |
Pollution degree | 2 |
Relative Humidity | 20 ... 85 % |
Medium conditions | |
Dielectric constant | dK ≥ 1.4 (configuration dependent) |
Note: for measurement below 1.4 use probe end tracking. | |
Process temperature range | -196 ... +450 °C (-321 ... +842 °F) |
Vessel pressure | -1 … +400 bar |