ABB TB55732600F15 TBX5 pH, Redox (ORP) sensors with diagnostics ,TB557 and TBX557 hot-tap retractable sensors
- Product description
- Contact us
ABB TB55732600F15 TBX5 pH, Redox (ORP) sensors with diagnostics ,TB557 and TBX557 hot-tap retractable sensors,TB557J1E74T20
Measurement made easy
The most durable pH / Redox (ORP) sensors in the world Next Step™ Solid State reference
• eliminates poisoning, pumping and plugging Advantage™ series with solution ground rod
• permits continuous sensor diagnostics Comprehensive selection of measuring electrodes
• sensors designed to suit all application requirements Combination style construction
• measuring, reference and temperature elements, all in one compact body Insertion, submersion, flow-through and hot-tap
• increases flexibility of installation Operating temperatures up to 140 °C (284 °F)
• the highest glass temperature limit on the market Operating pressures up to 21 bar (300 psi) and higher
• the highest pressure limit on the market
Body style
Sensor bodies are constructed of Kynar (PVDF) or Ryton (PPS). TB5 series sensors use Solid-State Next Step
references. The TBX5 series denotes Next Step Advantage types with integral solution ground.
TB557 and TBX557 hot-tap retractable sensors
TB(X)557 sensors are hot-tap, ball valve insertion sensors.They enable sensor maintenance or replacement without interrupting the process.
An integral safety anti-blowout lip is incorporated into the sensor design, preventing accidental sensor removal.
Unlike chain restraints, this safety-by-design is an integral part of the sensors' construction.
The sensor is inserted through a standard 11/2 in. or 11/4 in.full port ball valve which is sold seperately.
Connection to a ball valve is by compression fitting available in either hand-tight with 11/4 in. NPT threads or wrench-tight with
1 in. NPT threads. Additional fittings enable the assembly to be flushed and drained in situ and use a 11/2 in. NPT thread for connection to the ball valve.
Specification
Applications
Insertion, hot-tap
Maximum pressure / temperature
690 kPa (100 psi) at 80 °C (176 °F)
276 kPa (40 psi) at 140 °C (284 °F)
Features
Insert / retract without disturbing process flow
Replaceable electrode
Anti-blowout lip
No internal high-impedance connection
Material
Electrode Body Kynar (PVDF) as standard
Sensor sheath 316 stainless steel
variants Hastelloy or Titanium
External O-rings Viton
Junction Wood or PTFE
Junction types Flush (flat only)
Notched
Lengths Standard 406 mm (16 in.)
Maximum 1524 mm (60 in.)
ABB TBX5 Series
TB551 and TBX551 Ryton sensors
TB556 and TBX556 Kynar sensors
TB557 and TBX557 hot-tap retractable sensors
TB561 and TBX561 Sterilizable sensors
TB564 and TBX564 high pressure hot-tap retractable sensors
TB567 and TBX567 high pressure in-line sensors
There have More items , all for 100% New & Original with very good discount , pls kindly contact with Chris directly to know more details information .
Chris Fang
Sales Engineer
Sunup (Wuhan) Import and Export Co., Ltd.
Add:7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan, China
Postal code:430015
M: + 86-15926376631(WhatsApp & Wechat) |
Skype: live:chris_61491
Email: chris@sunupauto.com