Original EMERSON ROSEMOUNT 5081-A-HT-20-73 5081 Amperometric Transmitter
- Product description
- Contact us
EMERSON ROSEMOUNT 5081-A-HT-20-73 5081 Amperometric Transmitter
TwO-wIRE TRANSmITTERS FOR pH, ORP,CONDUCTIvITy, OxygEN, OzONE, AND CHLORINE
5081 Family of Two-wire Transmitters
• CHOICE OF COMMUNICATION PROTOCOL: HART® or FOUNDATION Fieldbus.
• LARGE, EASY-TO-READ two-line display shows the process measurement and temperature.
• SIMPLE MENU STRUCTURE.
• ROBUST TYPE 4X ENCLOSURE.
• INTRINSICALLY SAFE DESIGN allows the transmitter to be used in hazardous environments (with appropriate safety barriers).
• NON-VOLATILE MEMORY retains program settings and calibration data during power failures
5081-P pH/ORP Transmitter
• CHANGING FROM pH TO ORP operation takes only seconds.
• AUTOMATIC TWO-POINT BUFFER CALIBRATION reduces errors.
• SOLUTION TEMPERATURE COMPENSATION converts measured pH to the pH at 25°C.
• CONTINUOUS DIAGNOSTICS monitor sensor performance and warn the user of failure (FAULT) or approaching failure (WARNING).
5081-C Contacting Conductivity Transmitter
• MEASURES CONDUCTIVITY, RESISTIVITY, OR CUSTOM CURVE VARIABLE.
• AUTOMATIC TC RECOGNITION simplifies start up.
• AUTOMATIC/MANUAL TEMPERATURE COMPENSATION ensures accurate monitoring and control.
• AUTOMATIC COMPENSATION FOR SENSOR CABLE RESISTANCE improves accuracy of high conductivity/ low resistivity measurements.
• BUILT-IN TEMPERATURE COMPENSATION ALGORITHMS include straight slope, ultrapure water, cation conductivity, and no compensation.
5081-T Toroidal Conductivity Transmitter
• MEASURES CONDUCTIVITY, PERCENT CONCENTRATION, OR CUSTOM CURVE VARIABLE.
• AUTOMATIC TC RECOGNITION simplifies start up.
• AUTOMATIC/MANUAL TEMPERATURE COMPENSATION ensures accurate monitoring and control.
• BUILT-IN CONCENTRATION CURVES FOR 0-12% NaOH, 0-15% HCl, 0-25% and 96-99.7% H2SO4.
• PROGRAMMABLE REFERENCE TEMPERATURE enables temperature compensation to temperatures other than 25 degrees Celsius.
• AUTOMATIC COMPENSATION FOR SENSOR CABLE RESISTANCE improves accuracy of high conductivity measurements.
5081-A Amperometric Transmitter
• MEASURES dissolved oxygen (ppm and ppb level), free chlorine, total chlorine, and ozone.
• SECOND INPUT FOR A pH SENSOR ALLOWS AUTOMATIC pH CORRECTION for free chlorine measurement.
No expensive, messy reagents needed.
• AUTOMATIC BUFFER RECOGNITON FOR pH CALIBRATION.
ORDERINg INFORmATION
The 5081 Two-wire Transmitter is intended for the determination of pH/ORP, conductivity (both contacting and
toroidal), and for measurements using membrane-covered amperometric sensors (oxygen, ozone, and chlorine).
For free chlorine measurements, which often require continuous pH correction, a second input for a pH sensor is
available. A hand-held infrared remote controller is required for local configuration and calibration of the transmitter.
Model No Example
5081-P-HT-20-69
5081-P-HT-20-73
5081-P-HT-21-60
5081-P-HT-21-67
5081-P-HT-21-69
5081-P-HT-21-73
5081-P-FF-20-60
5081-P-FF-20-67
5081-P-FF-20-69
5081-P-FF-20-73
5081-P-FF-21-60
5081-P-FF-21-67
5081-P-FF-21-69
5081-P-FF-21-73
5081-P-FI-20-60
5081-P-FI-20-67
5081-P-FI-20-69
5081-P-FI-20-73
5081-P-FI-21-60
5081-P-FI-21-67
5081-P-FI-21-69
5081-P-FI-21-73
5081-C-HT-20-60
5081-C-HT-20-67
5081-C-HT-20-69
5081-C-HT-20-73
5081-C-HT-21-60
5081-C-HT-21-67
5081-C-HT-21-69
5081-C-HT-21-73
5081-C-FF-20-60
5081-C-FF-20-67
5081-C-FF-20-69
5081-C-FF-20-73
5081-C-FF-21-60
5081-C-FF-21-67
5081-C-FF-21-69
5081-C-FF-21-73
5081-C-FI-20-60
5081-C-FI-20-67
5081-C-FI-20-69
5081-C-FI-20-73
5081-C-FI-21-60
5081-C-FI-21-67
5081-C-FI-21-69
5081-C-FI-21-73
5081-T-HT-20-60
5081-T-HT-20-67
5081-T-HT-20-69
5081-T-HT-20-73
5081-T-HT-21-60
5081-T-HT-21-67
5081-T-HT-21-69
5081-T-HT-21-73
5081-T-FF-20-60
5081-T-FF-20-67
5081-T-FF-20-69
5081-T-FF-20-73
5081-T-FF-21-60
5081-T-FF-21-67
5081-T-FF-21-69
5081-T-FF-21-73
5081-T-FI-20-60
5081-T-FI-20-67
5081-T-FI-20-69
5081-T-FI-20-73
5081-T-FI-21-60
5081-T-FI-21-67
5081-T-FI-21-69
5081-T-FI-21-73
5081-A-HT-20-60
5081-A-HT-20-67
5081-A-HT-20-69
5081-A-HT-20-73
5081-A-HT-21-60
5081-A-HT-21-67
5081-A-HT-21-69
5081-A-HT-21-73
5081-A-FF-20-60
5081-A-FF-20-67
5081-A-FF-20-69
5081-A-FF-20-73
5081-A-FF-21-60
5081-A-FF-21-67
5081-A-FF-21-69
5081-A-FF-21-73
5081-A-FI-20-60
5081-A-FI-20-67
5081-A-FI-20-69
5081-A-FI-20-73
5081-A-FI-21-60
5081-A-FI-21-67
5081-A-FI-21-69
5081-A-FI-21-73
There have More items , all for 100% New & Original with very good discount , pls kindly contact with Chris directly to know more details information .
Chris Fang
Sales Engineer
Sunup (Wuhan) Import and Export Co., Ltd.
Add:7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan, China
Postal code:430015
M: + 86-15926376631(WhatsApp & Wechat)
Skype: live:chris_61491
Email: chris@sunupauto.com