HOT SALE FUJI FKCR49V5-2XCEN-CW DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FKC...5 Brand New with Good Discount
- Product description
- Contact us
FUJI FKCR49V5-2XCEN-CW DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FKC...5
The FCX-AII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge
pressure or flow rate and transmits a proportional 4 to 20mA signal.
The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor
technology to provide exceptional performance and functionality.
FEATURES
1. High accuracy up to ±0.04% 0.065% accuracy as standard, 0.04% accuracy as option. Fuji’s micro-capacitance
silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment.
2. Minimum environmental influence
The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure,
and overpressure substantially reduces total measurement error in actual field applications.
3. Fuji/HART® bilingual communications protocol
FCX–AII series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®.
Any HART® compatible devices can communicate with FCX-AII
4. Application flexibility
Various options that render the FCX–AII suitable for almost any process applications include.
– Full range of hazardous area approvals
– Built-in RFI filter and lightning arrester
– 5-digit LCD meter with engineering unit
– Stainless steel electronics housing
– Wide selection of materials
5. Programmable output Linearization Function
In addition to Linear and Square Root, output signal can be freely programmable.
(Up to 14 compensated points at approximation.)
6. Burnout current flexibility (Under Scale: 3.2 to 4.0mA, Over Scale: 20.0 to 22.5mA)
Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with NAMUR NE43.
7. Dry calibration without reference pressure
Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics
circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration.
Over range limit :
To maximum static pressure limit
Output signal :
4 to 20mA DC (linear or square root) with digital signal
superimposed on the 4 to 20mA signal
Power supply :
Transmitter operates on 10.5V to 45V DC at transmitter
terminals.
10.5V to 32V DC for the units with optional arrester.
Load limitations :see figure below
Model No Examples
FKCW33V5-5XCEN-CW
FKCW35V5-5XCEY-CU
FKCR22V5-AXAYY-AU
FKCR36V5-AXAYY-AU
FKCR33V5-AXAYY-AU
FKCX22V5-AXAYY-AV
FKCX36V5-AXAYY-AY
FKCX33V5-AXAYY-AV
FKCT35V5-BDFBY-BE
FKCT35V5-BDFBY-BE
FKCW35H5-2KCEN-CU
FKCR49V5-2XCEN-CW
FKCW33H5-2KCEN-CU
There have More FUJI items , all for 100% New & Original with very good discount , pls kindly contact with Chris directly to know more details information .
Chris Fang
Sales Engineer
Sunup (Wuhan) Import and Export Co., Ltd.
Add:7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan, China
Postal code:430015
M: + 86-15926376631(WhatsApp & Wechat) |
Skype: live:chris_61491
Email: chris@sunupauto.com
Web: http://www.sunup-automation.com