Products

MTL3046B REPEATER POWER SUPPLY Brand New with Good Discount

100% New & Original with very competitive price and One year Warranty
MTL3046B
MTL3046B REPEATER POWER SUPPLY Brand New with Good Discount
Please contact us for more information.

MTL3046B REPEATER POWER SUPPLY 4/20mA for smart transmitters



The MTL3046B performs a similar function to the MTL3041, but is tailored for use with ‘smart’ transmitters whose digital communication

signals are superimposed on a standard 4/20mA analogue signal. The unit provides a minimum of 15V at 20mA to energise the

transmitter while at the same time repeating the current accurately in a separate circuit to drive a load in the safe area. The transmitter can

be calibrated, interrogated or tested from the host computer, or by using a hand-held communicator connected in either the safe or

hazardous area. The MTL3046B is a development of the MTL3046, which it replaces, and it is compatible with the majority of ‘smart’ transmitters available


SPECIFICATION

See also 'Common specification'

Number of channels

One, fully floating

Location of transmitter

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div 1, Group A, hazardous location

Voltage available for transmitter and lines

15V minimum at 20mA

Note: maximum open-circuit voltage is 28V

Maximum permitted line resistance

[(15 minus transmitter voltage requirement) x 50] Ω

Input and output signal range

4 to 20mA with superimposed digital signal

Digital signal bandwidth (safe area to hazardous area)

10Hz to 8kHz

Digital signal bandwidth (hazardous area to safe area)

dc to 10kHz

Input resistance (terminals 6 & 8)

≤30Ω (600mV at 20mA)

Safe-area circuit load resistance

20 to 750Ω (250Ω ±10% for digital communications)

Safe-area circuit output resistance

>1MΩ

Safe-area circuit ripple

<160µA peak-to-peak

DC transfer accuracy at 20°C

Better than 20µA

Temperature drift

<1µA/°C

Response time

Settles to within 10% of final value after typically 40µs

Power requirement

85mA typically at 24V with 20mA signal

75mA at 35V to 125mA at 20V with 20mA signal

Power dissipation within unit

1.7W typical at 24V with 20mA signal

2.3W maximum at 35V with 20mA signal

Replaceable fuse

200mA, 5x20mm glass to DIN 41571 sht.2, semi-time-lag (M)

Safety description

Terminals 5 & 6

28V, 300Ω, 93mA, Um = 250V rms or dc

Terminals 6 & 8

Non-energy storing apparatus – ≤1.2V, ≤0.1A, ≤20µJ and

≤25mW. Can be connected without further certification into any

IS loop with open-circuit voltage not more than 28V.

Note: Terminals 6 & 8 do not support bi-directional transmissions for

HART®devices

FM max entity parameters

Terminals 5 & 6: Voc = 28V, Isc = 93mA, Ca = 0.13µF, La =

4.0mH

Terminals 6 & 8: Voc = 1.2V, Isc = 100mA, Ca = 1000µF, La =

3.75mH

Weight

170g


image


MTL7000 series

MTL7028 

MTL7055 

MTL7056 

MTL7060 

MTL7066 

MTL7087 

MTL7096 

MTL7099

MTL7106 

MTL7122 

MTL7128 

MTL7129 

MTL7160 

MTL7161 

MTL7164 

MTL7187

MTL7206 

MTL7207 

MTL7208 

MTL7261 

MTL7264 

MTL7265 

MTL7287 

MTL7299

MTL7788 

MTL7789 

MTL702+ 

MTL705+ 

MTL706+ 

MTL707+ 

MTL707P+ 

MTL708+ 

MTL710+ 

MTL710- 

MTL710AC

MTL710P+ 

MTL710P- 

MTL715+ 

MTL715- 

MTL715P+ 

MTL722+ 

MTL722- 

MTL722P+

MTL728+ 

MTL728- 

MTL728AC 

MTL728P+ 

MTL729P+ 

MTL751AC

MTL7796 

MTL7798 

MTL7799

MTL755AC


MTL4500 Series : 

MTL4524S

MTL4525 

MTL4526 

MTL4541

MTL4541A

MTL4541AS

MTL4541B

MTL4541P

MTL4541S

MTL4541T

MTL4544

MTL4544A

MTL4544AS

MTL4544B

MTL4544D

MTL4544S

MTL4546

MTL4546C

MTL4546S

MTL4546Y 

MTL4549

MTL4549C

MTL4549Y

MTL4573

MTL4575

MTL4576-RTD

MTL4576-THC

MTL4581

MTL4582B

MTL4531

MTL4532 

MTL4561

MTL4599 

MTL4599N

MTL4500-5500-ACC 

MTL4500-5500-CS 

MTL4500-5500-DS 

MTL4501-SR

MTL4504

MTL4510 

MTL4510B

MTL4511

MTL4513

MTL4514D

MTL4514N

MTL4514_B

MTL4516

MTL4516C

MTL4517

MTL4521

MTL4521L

MTL4523

MTL4523L

MTL4523R

MTL4523V-VL 


MTL5500 Series : 

MTL5501-SR

MTL5510

MTL5510B

MTL5511

MTL5513

MTL5514

MTL5514-T

MTL5514D

MTL5516C

MTL5517 

MTL5521

MTL5521-T

MTL5522

MTL5523

MTL5523V – VL

MTL5524

MTL5525

MTL5526

MTL5541

MTL5541A

MTL5541AS

MTL5541S

MTL5541S-T

MTL5544

MTL5544A

MTL5544AS 

MTL5544D

MTL5544S 

MTL5546

MTL5546Y

MTL5546Y-T

MTL5549

MTL5549Y

MTL5573

MTL5575

MTL5576-RTD

MTL5576-THC 

MTL5581

MTL5582

MTL5582B

MTL5531

MTL5532

MTL5561

MTL5051

MTL5314

MTL5553

MTL5599 


MTL5544D



There have More MTL items , all for 100% New & Original with very good discount , pls kindly contact with Chris directly to know more details information . 


Chris Fang 

Sales Engineer


Sunup (Wuhan) Import and Export Co., Ltd.

Add:7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan, China

Postal code:430015

M:  + 86-15926376631(WhatsApp & Wechat) |

Skype: live:chris_61491

Email: chris@sunupauto.com

Web: http://www.sunup-automation.com

Copyright © 2019 Sunup (Wuhan) Industrial Equipment Co., Ltd. All Right Reserved.


Sunup (Wuhan) Industrial Equipment Co., Ltd is not an authorized reseller, agent or affiliate of any brand or manufacturer. All trademarks, brand names and logos whose products are sold on the website are used for identification purposes only and are registered trademarks of their respective owners, all rights reserved. The use of a trademark, brand name or product on our website does not imply that the company trademark or brand belongs to or endorses our website. All products are 100% original, genuine and legally purchased from authorized sources.