MTL4013 SWITCH/ PROXIMITY DETECTOR INTERFACE
two-channel, solid-state output
The MTL4013 is a two-channel unit enabling safe-area loads to be controlled, through logic compatible solid-state outputs,
by switches or proximity detectors located in hazardous areas. It can also be used with positive displacement (PD)
flowmeters and some turbine meters. Earth fault detection is available optionally by using the MTL4013
with an MTL4220 earth leakage detector. Power and switch status is indicated by LEDs located on top of the module.
SPECIFICATION
See also common specification, cable parameters and
approvals
Number of channels
Two
Location of switches
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 if suitably certified
Div.1, Group A, hazardous location
Voltage applied to sensor
7.0V – 9.0V dc from 1kΩ
Input/output characteristics
Output on if >2.1mA* (<2kΩ) in sensor circuit
Output off if <1.2mA* (>10kΩ) in sensor circuit
Hysteresis: 200µA (650Ω) nominal
*NAMUR and DIN 19234 standards for proximity
detectors
‘No-fail’ earth fault protection
Enabled by connecting terminals 3 and 6 to an MTL4220 earth
leakage detector
Fault on either line proclaimed: unit continues working
Note: if it is required to maintain isolation between the two channels,
separate earth leakage detectors are needed
Output characteristics
Operating frequency: dc to 5kHz
Maximum off-state voltage: 35V
Maximum off-state leakage current: 10µA
Maximum on-state voltage drop: [1+ (0.1 x current in mA)] V
Maximum on-state current: 50mA
Note: each output is Zener-diode protected against inductive
loads
LED indicators
Amber: one provided for each channel, ON when output circuit
is closed
Green: one provided for power indication
Power requirement, Vs
47.5mA at 24V dc
45mA at 20V dc
50mA at 35V dc
Power dissipation within unit
1.15W at 24V
1.75W at 35V
Isolation
250V ac between safe and hazardous area circuits
Safety description for each channel
10.5V, 800Ω, 14mA
FM entity parameters
Voc = 10.5V dc, Isc = 14mA, Ca = 2.4µF, La = 165mH
MTL7000 series
MTL7028
MTL7055
MTL7056
MTL7060
MTL7066
MTL7087
MTL7096
MTL7099
MTL7106
MTL7122
MTL7128
MTL7129
MTL7160
MTL7161
MTL7164
MTL7187
MTL7206
MTL7207
MTL7208
MTL7261
MTL7264
MTL7265
MTL7287
MTL7299
MTL7788
MTL7789
MTL702+
MTL705+
MTL706+
MTL707+
MTL707P+
MTL708+
MTL710+
MTL710-
MTL710AC
MTL710P+
MTL710P-
MTL715+
MTL715-
MTL715P+
MTL722+
MTL722-
MTL722P+
MTL728+
MTL728-
MTL728AC
MTL728P+
MTL729P+
MTL751AC
MTL7796
MTL7798
MTL7799
MTL755AC
MTL4500 Series :
MTL4524S
MTL4525
MTL4526
MTL4541
MTL4541A
MTL4541AS
MTL4541B
MTL4541P
MTL4541S
MTL4541T
MTL4544
MTL4544A
MTL4544AS
MTL4544B
MTL4544D
MTL4544S
MTL4546
MTL4546C
MTL4546S
MTL4546Y
MTL4549
MTL4549C
MTL4549Y
MTL4573
MTL4575
MTL4576-RTD
MTL4576-THC
MTL4581
MTL4582B
MTL4531
MTL4532
MTL4561
MTL4599
MTL4599N
MTL4500-5500-ACC
MTL4500-5500-CS
MTL4500-5500-DS
MTL4501-SR
MTL4504
MTL4510
MTL4510B
MTL4511
MTL4513
MTL4514D
MTL4514N
MTL4514_B
MTL4516
MTL4516C
MTL4517
MTL4521
MTL4521L
MTL4523
MTL4523L
MTL4523R
MTL4523V-VL
MTL5500 Series :
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513
MTL5514
MTL5514-T
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5521-T
MTL5522
MTL5523
MTL5523V – VL
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS
MTL5541S
MTL5541S-T
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5546Y-T
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5531
MTL5532
MTL5561
MTL5051
MTL5314
MTL5553
MTL5599
There have More MTL items , all for 100% New & Original with very good discount , pls kindly contact with Chris directly to know more details information .
Chris Fang
Sales Engineer
Sunup (Wuhan) Import and Export Co., Ltd.
Add:7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan, China
Postal code:430015
M: + 86-15926376631(WhatsApp & Wechat) |
Skype: live:chris_61491
Email: chris@sunupauto.com