SITOP PSU200M 24 V/10 A SITOP PSU200M 10 A Stabilized power supply input: 120/230-500 V AC output: DC 24 V/10 A


Input

Input 1-phase and 2-phase AC

● Note Set by means of selector switch on the device

Supply voltage

● 1 at AC 120 ... 230 V

● 2 at AC 230 ... 500 V

Input voltage

● 1 at AC 85 ... 264 V

● 2 at AC 176 ... 550 V

Wide-range input Yes

Overvoltage resistance 1300 Vpeak, 1.3 ms

Mains buffering at Vin = 120/230 V, typ. 150 ms at Vin = 400 V

Mains buffering at Iout rated, min. 25 ms; at Vin = 120/230 V, typ. 150 ms at Vin = 400 V

Rated line frequency 1 50 Hz

Rated line frequency 2 60 Hz

Rated line range 47 ... 63 Hz

Input current

● at rated input voltage 120 V 4.4 A

● at rated input voltage 230 V 2.4 A

● at rated input voltage 500 V 1.1 A

Switch-on current limiting (+25 °C), max. 35 A

I²t, max. 4 A²·s

Built-in incoming fuse T 6.3 A (not accessible)

Protection in the mains power input (IEC 898) Recommended miniature circuit breaker at 1-phase operation:

from 6 A (10 A) characteristic C (B); required at 2-phase

operation: circuit breaker 2-pole connected or circuit breaker

3RV2011-1EA10 (setting 3.8 A) or 3RV2711-1ED10 (UL 489) at

230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL

489) at 400/500 V


Output

Output Controlled, isolated DC voltage

Rated voltage Vout DC 24 V

Total tolerance, static ± 3 %

Static mains compensation, approx. 0.1 %

Static load balancing, approx. 0.1 %

Residual ripple peak-peak, max. 50 mV

Spikes peak-peak, max. (bandwidth: 20 MHz) 200 mV

Adjustment range 24 ... 28.8 V

Product function Output voltage adjustable Yes

Output voltage setting via potentiometer

Status display Green LED for 24 V OK

Signaling Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"

On/off behavior Overshoot of Vout approx. 3 %

Startup delay, max. 1 s

Voltage rise, typ. 50 ms

Rated current value Iout rated 10 A

Current range 0 ... 10 A

● Note +60 ... +70 °C: Derating 2%/K (at 120 V, 230 V) or 3.5%/K (at 400

V)

Supplied active power typical 240 W

Short-term overload current

● at short-circuit during operation typical 30 A

Duration of overloading capability for excess current

● at short-circuit during operation 25 ms

Constant overload current

● on short-circuiting during the start-up typical 12 A

Parallel switching for enhanced performance Yes; switchable characteristic

Numbers of parallel switchable units for enhanced

performance

2


Efficiency

Efficiency at Vout rated, Iout rated, approx. 91 %

Power loss at Vout rated, Iout rated, approx. 24 W

Power loss [W] during no-load operation maximum 6 W

Closed-loop control

Dynamic mains compensation (Vin rated ±15 %),

max.

0.1 %

Dynamic load smoothing (Iout: 50/100/50 %), Uout ±

typ.

3 %

Load step setting time 50 to 100%, typ. 2 ms

Load step setting time 100 to 50%, typ. 2 ms

Setting time maximum 5 ms

Protection and monitoring

Output overvoltage protection < 35 V

Current limitation, typ. 12 A

Property of the output Short-circuit proof Yes

Short-circuit protection Alternatively, constant current characteristic approx. 12 A or

latching shutdown

Enduring short circuit current RMS value

● typical 12 A

Overload/short-circuit indicator LED yellow for "overload", LED red for "latching shutdown"

Safety

Primary/secondary isolation Yes

Galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN

50178

Protection class Class I

Leakage current

● maximum 3.5 mA

● typical 0.32 mA

Degree of protection (EN 60529) IP20

Approvals

CE mark Yes

UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259,

cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)

Explosion protection IECEx Ex nA nC IIC T4 Gc; ATEX (EX) II 3G Ex nA nC IIC T4 Gc;

cCSAus (CSA C22.2 No. 213, ANSI/ISA-12.12.01) Class I, Div. 2,

Group ABCD, T3

FM approval -

CB approval Yes

Marine approval ABS, DNV GL


Width of the enclosure 70 mm

Height of the enclosure 125 mm

Depth of the enclosure 121 mm

Weight, approx. 0.8 kg


6EP1334-3BA01 details1


6EP1334-3BA01 details2

Copyright © 2019 Sunup (Wuhan) Industrial Equipment Co., Ltd. All Right Reserved.


Sunup (Wuhan) Industrial Equipment Co., Ltd is not an authorized reseller, agent or affiliate of any brand or manufacturer. All trademarks, brand names and logos whose products are sold on the website are used for identification purposes only and are registered trademarks of their respective owners, all rights reserved. The use of a trademark, brand name or product on our website does not imply that the company trademark or brand belongs to or endorses our website. All products are 100% original, genuine and legally purchased from authorized sources.