Product Description
TRIO POWER power supplies with standard functionality
The TRIO POWER power supply range with push-in connection has been perfected for use in machine building.
All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements.
Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads.
Key Commercial Data
Orderkey | 2903160 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 261 (C-4-2019) |
GTIN | 4055626255415 |
Weight per Piece (excluding packing) | 1,620.000 g |
Custom tariff number | 85044030 |
Country of origin | CN (China) |
Dimensions
Width | 68 mm |
---|---|
Height | 130 mm |
Depth | 160 mm |
Ambient conditions
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) | -40 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Installation height | ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) |
Input data
Nominal input voltage range | 100 V AC ... 240 V AC |
---|---|
110 V DC ... 250 V DC | |
Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
99 V DC ... 275 V DC | |
Dielectric strength maximum | ≤ 300 V AC 15 s |
AC frequency range | 50 Hz ... 60 Hz ±10 % |
Discharge current to PE | < 3.5 mA |
Current consumption | 5.6 A (100 V AC) |
5.4 A (120 V AC) | |
2.6 A (230 V AC) | |
2.4 A (240 V AC) | |
Nominal power consumption | 604.7 VA |
Inrush current | 20 A (at 25 °C) |
Mains buffering time | typ. 10 ms (120 V AC) |
typ. 15 ms (230 V AC) | |
Input fuse | 10 A (internal (device protection)) |
Recommended breaker for input protection | 10 A ... 16 A (Characteristics B, C, D, K) |
Power factor (cos phi) | 0.85 |
Type of protection | Transient surge protection |
Protective circuit/component | Varistor |
Output data
Nominal output voltage | 48 V DC ±1 % |
---|---|
Setting range of the output voltage (USet) | 36 V DC ... 55 V DC (> 48 V DC, constant capacity restricted) |
Nominal output current (IN) | 10 A |
Dynamic Boost (IDyn.Boost) | 15 A (5 s) |
Derating | > 60 °C ... 70 °C (2.5%/K) |
Connection in parallel | Yes, for redundancy and increased capacity |
Connection in series | yes |
Feedback voltage resistance | ≤ 60 V DC |
Protection against overvoltage at the output (OVP) | ≤ 60 V DC |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 50 mVPP (with nominal values) |
Output power | 480 W |
Typical response time | < 1 s |
Peak switching voltages nominal load | < 1000 mVPP |
Maximum power dissipation in no-load condition | < 5.7 W (230 V) |
Power loss nominal load max. | < 44 W |
General
Net weight | 1.4 kg |
---|---|
Efficiency | > 93 % (for 230 V AC and nominal values) |
Insulation voltage input/output | 3 kV AC |
1.5 kV AC | |
Protection class | I (in closed control cabinet) |
Degree of protection | IP20 |
MTBF (IEC 61709, SN 29500) | > 1800000 h (25 °C) |
> 800000 h (40 °C) | |
> 480000 h (60 °C) | |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm |
Connection data, input
Connection method | Push-in connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 4 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 10 mm |
Connection data, output
Connection method | Push-in connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 10 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 6 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 8 |
Stripping length | 15 mm |
Connection data for signaling
Connection method | Push-in connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Standards
EMC requirements for noise immunity | EN 61000-6-1 |
---|---|
EN 61000-6-2 | |
EMC requirements for noise emission | EN 61000-6-3 |
EN 61000-6-4 | |
Standard - Safety of transformers | EN 61558-2-16 (air clearances and creepage distances only) |
Standard - Electrical safety | IEC 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage | IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Rail applications | EN 50121-4 |