Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 24 V DC/5 A



Product Description

TRIO POWER power supplies for more stringent EMC requirements in shipbuilding
The TRIO POWER power supply range with Push-in connection has been perfected for use in shipbuilding. All functions and the space-saving design 

of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, 

the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads.


Key Commercial Data

Orderkey2903144
Packing unit1 pc
Catalog pagePage 255 (C-4-2019)
GTIN4046356726955
Weight per Piece (excluding packing)0.560 g
Custom tariff number85044030
Country of originCN (China)


Dimensions

Width35 mm
Height130 mm
Depth115 mm


Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height≤ 5000 m (> 2000 m, observe derating)


Input data

Nominal input voltage range100 V AC ... 240 V AC

110 V DC ... 250 V DC
Input voltage range100 V AC ... 240 V AC -15 % ... +10 %

99 V DC ... 275 V DC
Dielectric strength maximum≤ 300 V AC 15 s
AC frequency range50 Hz ... 60 Hz ±5 Hz
Frequency range (fN)50 Hz ... 60 Hz ±10 %
Discharge current to PE< 0.25 mA
Current consumption2.2 A (100 V AC)

1.9 A (120 V AC)

1.1 A (230 V AC)

1.1 A (240 V AC)
Nominal power consumption272 VA
Inrush current≤ 16 A (typical)
Mains buffering timetyp. 20 ms (120 V AC)

typ. 100 ms (230 V AC)
Input fuse6.3 A (internal (device protection))
Recommended breaker for input protection6 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi)0.5
Type of protectionTransient surge protection
Protective circuit/componentVaristor


Output data

Nominal output voltage24 V DC ±1 %
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)5 A
Dynamic Boost (IDyn.Boost)7.5 A (5 s)
Derating> 60 °C ... 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 30 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %)

< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)

< 0.1 % (change in input voltage ±10 %)
Residual ripple< 50 mVPP (with nominal values)
Output power120 W
Typical response time< 1 s
Maximum power dissipation in no-load condition< 1 W


Power loss nominal load max.< 16 W


General

Net weight0.45 kg
Efficiency> 89 % (for 230 V AC and nominal values)
Insulation voltage input/output3 kV AC (type test)

1.5 kV AC (routine test)
Protection classII (in closed control cabinet)
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 3380000 h (25 °C)

> 1970000 h (40 °C)

> 900000 h (60 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm


Connection data, input

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm

Connection data, output

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length8 mm


Connection data for signaling

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm


Standards

EMC requirements for noise immunityEN 61000-6-1

EN 61000-6-2
EMC requirements for noise emissionEN 61000-6-3

EN 61000-6-4
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)
Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Mains variation/undervoltageSemi F47-0706
Rail applicationsEN 50121-4



2903144



Copyright © 2019 Sunup (Wuhan) Industrial Equipment Co., Ltd. All Right Reserved.


Sunup (Wuhan) Industrial Equipment Co., Ltd is not an authorized reseller, agent or affiliate of any brand or manufacturer. All trademarks, brand names and logos whose products are sold on the website are used for identification purposes only and are registered trademarks of their respective owners, all rights reserved. The use of a trademark, brand name or product on our website does not imply that the company trademark or brand belongs to or endorses our website. All products are 100% original, genuine and legally purchased from authorized sources.