Products

Phoenix Hybrid motor starter - ELR H5-IES-SC-230AC/500AC-9 - 2900422 New & Original with very competitive price and One year Warranty

New & Original
ELR H5-IES-SC-230AC/500AC-9 - 2900422
Phoenix Hybrid motor starter - ELR H5-IES-SC-230AC/500AC-9 - 2900422 New & Original with very competitive price and One year Warranty
Please contact us for more information.

Phoenix Hybrid motor starter - ELR H5-IES-SC-230AC/500AC-9 - 2900422




Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 230 V AC control voltage, 

adjustable overload shutdown and emergency stop function to SIL 3/PL e


Key Commercial Data

Orderkey2900422
Packing unit1 pc
Catalog pagePage 28 (C-5-2019)
GTIN4046356504683
Weight per Piece (excluding packing)280.000 g
Custom tariff number85371098
Country of originDE (Germany)


Dimensions

Width22.5 mm
Height107 mm
Depth114 mm


Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Degree of protectionIP20


Device supply

Rated control circuit supply voltage US230 V AC
Control supply voltage range85 V AC ... 253 V AC
Rated control supply current IS4 mA
Type of protectionSurge protection


Input data

Input nameControl input right/left
Rated actuating voltage UC230 V AC
Triggering voltage range85 V AC ... 253 V AC
Rated actuating current IC7 mA (Input type 1)
Switching threshold44 V AC (“0” signal)

85 V AC (“1” signal)
Switching level< 5 V AC (For EMERGENCY STOP)
Typical turn-off time< 70 ms

Output data load output

Output nameAC output
Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Rated operating current Ie9 A (AC-51)

6.5 A (AC-53a)
Load current range1.5 A ... 9 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2Class 10A
Cooling time20 min. (for auto reset)
Leakage current0 mA
Type of protectionSurge protection

Output data reply output

Output nameAcknowledge output
NoteConfirmation: floating change-over contact, signal contact
Contact type1 PDT
Switching capacity according to IEC 60947-5-13 A (230 V, AC15)

2 A (24 V, DC13)


Overspeed tripping

Operate threshold> 45 A
Response time< 2 s


General

Motor starter typeReversing starter
Switching frequency≤ 2 Hz (Load-dependent)
Mounting positionvertical (horizontal DIN rail, motor output below)
Mounting typeDIN rail mounting
Assembly instructionsalignable, for spacing see derating
Operating mode100% operating factor
Maximum power dissipation16.1 W
Minimum power dissipation2.6 W
Operating voltage displayGreen LED
Status displayYellow LED
IndicationRed LED


Connection data

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm

5 lbf-in. ... 7 lbf-in.


Connection data 2

Connection nameLoad circuit
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm

5 lbf-in. ... 7 lbf-in.


Insulation characteristics

Rated insulation voltage500 V
Rated surge voltage4 kV
Overvoltage categoryIII
Degree of pollution2
DesignationInsulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit
InsulationSafe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC

Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC

Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC
DesignationIsolation characteristics between the control input and control supply voltage to auxiliary circuit
InsulationSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC

Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC


Standards and Regulations

DesignationStandards/regulations
Standards/regulationsIEC 60947-1

IEC 60947-4-2

IEC 61508

ISO 13849


Conformance/approvals

DesignationATEX
Identification II (2) G [Ex e] [Ex d] [Ex px]

 II (2) D [Ex t] [Ex p]
CertificatePTB 07 ATEX 3145
DesignationUL approval
CertificateNLDX.E228652
DesignationSafety Integrity Level (SIL, IEC 61508)
Identification≤ 3
Additional textSafe shutdown
DesignationSafety Integrity Level (SIL, IEC 61508)
Identification2
Additional textMotor protection
DesignationPerformance Level (ISO 13849)
Identification≤ e
Additional textSafe shutdown
DesignationCategory (ISO 13849)
Identification≤ 3
Additional textSafe shutdown


Copyright © 2019 Sunup (Wuhan) Industrial Equipment Co., Ltd. All Right Reserved.


Sunup (Wuhan) Industrial Equipment Co., Ltd is not an authorized reseller, agent or affiliate of any brand or manufacturer. All trademarks, brand names and logos whose products are sold on the website are used for identification purposes only and are registered trademarks of their respective owners, all rights reserved. The use of a trademark, brand name or product on our website does not imply that the company trademark or brand belongs to or endorses our website. All products are 100% original, genuine and legally purchased from authorized sources.