IFM O1D105 Photoelectric distance sensor ,Laser sensors - Distance sensors type O1D
- Product description
- Contact us
IFM O1D105 Photoelectric distance sensor ,Laser sensors - Distance sensors type O1D
Reliable optical distance measurement with high ranges up to 10 m
Two switching outputs, one of them programmable as analogue output
Scalable measuring range and window function
Use in applications with background suppression
Excellent price/performance ratio
Product characteristics | |
---|---|
Electrical design | PNP |
Output function | normally open / normally closed; (programmable) |
Communication interface | IO-Link |
Housing | rectangular |
Dimensions [mm] | 59 x 42 x 52 |
Electrical data | |
Operating voltage [V] | 18...30 DC |
Current consumption [mA] | < 150 |
Protection class | III |
Reverse polarity protection | yes |
Typ. lifetime [h] | 50000 |
Inputs / outputs | |
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs | |
Total number of outputs | 2 |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (programmable) |
Max. current load per output [mA] | 200 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4...20; (scalable IEC 61131-2) |
Max. load [Ω] | 250 |
Analogue voltage output [V] | 0...10; (scalable IEC 61131-2) |
Min. load resistance [Ω] | 5000 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Detection zone | |
Max. light spot width [mm] | 15 |
Max. light spot height [mm] | 15 |
Light spot dimensions refer to | 10 m |
Background suppression [m] | 10...100 |
Measuring/setting range | |
Measuring range [m] | 0.2...10; (white paper 200 x 200 mm 90 % remission) |
Sampling rate [Hz] | 1...33 |
Interfaces | |
Communication interface | IO-Link |
Transmission type | COM2 (38.4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
IO-Link device ID | 806 d / 00 03 29h |
Profiles | Smart Sensor: Device Identification; Device Diagnosis; Device Teach Channel; Binary Data Channel; Process Data Variable |
SIO mode | yes |
Required master port type | A |
Process data analogue | 2 |
Process data binary | 2 |
Min. process cycle time [ms] | 6 |
Operating conditions | |
Ambient temperature [°C] | -10...60 |
Protection | IP 67 |