Schneider LTMR08CFM Motor controller LTMR TeSys T - 100..240 V AC 8 A for CANopen
New & Original with very competitive price and One year Warranty
TeSys T is a smart motor management system. When associated with a short circuit protection device and a contactor,
the device provides full motor monitoring, control and protection for electrical motors.
range | TeSys | |
---|---|---|
product name | TeSys T | |
device short name | LTMR | |
product or component type | Motor controller | |
device application | Equipment monitoring and control | |
measurement current | 0.4…8 A | |
[Us] rated supply voltage | 100...240 V AC 50/60 Hz | |
current consumption | 8...62.8 mA | |
supply voltage limits | 93.5…264 V AC | |
communication port protocol | CANopen | |
bus type | CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cable CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, terminal block with 4 twisted shielded pairs cable |
[Ui] rated insulation voltage | 690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508 | |
---|---|---|
[Uimp] rated impulse withstand voltage | 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 | |
short-circuit withstand | 100 kA conforming to EN/IEC 60947-4-1 | |
associated fuse rating | 4 A gG for output 0.5 A gG for control circuit | |
protection type | Power factor variation Reverse polarity protection Thermal protection Phase failure Load fluctuation Overload Phase unbalance Thermal overload protection Overload (long time) Locked rotor Earth-leakage protection | |
network and machine diagnosis type | Event recording Trip history information Phase fault and earth fault trip counters Trip context information Waiting time after overload tripping Remaining operating time before overload tripping Running hours counter/operating time Motor control command recording Starting current and time Fault recording | |
logic input number | 6 | |
input current | 3.1 mA at 100 V 7.5 mA at 240 V | |
current state 0 guaranteed | Logic input: 0...40 V and <= 15 mA for 25 ms | |
current state 1 guaranteed | Logic input: 79...264 V and >= 2 mA for 25 ms | |
maximum output switching frequency | 2 Hz | |
load current | 5 A at 250 V AC for logic output 5 A at 30 V DC for logic output | |
permissible power | 480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) | |
maximum operating rate | 1800 cyc/h | |
contacts type and composition | 1 NO + 1 NC fault signal 3 NO | |
metering type | Temperature Phase current I1, I2, I3 RMS Imbalance current Average current Iavg Earth-fault current | |
measurement accuracy | 5...15 % earth fault current internal measurement (for current > 0.1 A) 1 % voltage (100...830 V) 3 % power factor (cos φ > 0.6) 5 % earth fault current external measurement (< 5 % or 0.01 A) +/- 30 min/year internal clock 0,02 temperature 1 % current 5 % active and reactive power |