Products

Schneider LTMR08CBD TeSys Motor controller New & Original with very competitive price and One year Warranty

New & Original
LTMR08CBD
Schneider LTMR08CBD TeSys Motor controller New & Original with very competitive price and One year Warranty
Please contact us for more information.

Schneider LTMR08CBD TeSys Motor controller New & Original with very competitive price and One year Warranty 




Tesys T

Smart motor management system

Part of TeSys

TeSys T is a smart motor management system. When associated with a short circuit protection device and a contactor, 

the device provides full motor monitoring, control and protection for electrical motors.



Main
rangeTeSys
product nameTeSys T
device short nameLTMR
product or component typeMotor controller
device applicationEquipment monitoring and control
measurement current0.4…8 A
[Us] rated supply voltage24 V DC
current consumption56...127 mA
supply voltage limits20.4…26.24 V DC
communication port protocolCANopen
bus typeCANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cable
CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, terminal block with 4 twisted shielded pairs cable

Complementary
[Ui] rated insulation voltage690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508

[Uimp] rated impulse withstand voltage6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1

short-circuit withstand100 kA conforming to EN/IEC 60947-4-1
associated fuse rating4 A gG for output
0.5 A gG for control circuit

protection typeOverload (long time)
Phase failure
Load fluctuation
Phase imbalance
Reverse polarity protection
Thermal protection
Thermal overload protection
Earth-leakage protection
Power factor variation
Overload
Locked rotor

network and machine diagnosis typeTrip context information
Remaining operating time before overload tripping
Starting current and time
Event recording
Motor control command recording
Running hours counter/operating time
Waiting time after overload tripping
Trip history information
Phase fault and earth fault trip counters
Fault recording

logic input number6
input current7 mA
current state 0 guaranteedLogic input: < 5 V and <= 15 mA for 5 ms
current state 1 guaranteedLogic input: < 15 V and 2...15 mA for 15 ms
maximum output switching frequency2 Hz
load current5 A at 250 V AC for logic output
5 A at 30 V DC for logic output

permissible power480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)

maximum operating rate1800 cyc/h
contacts type and composition1 NO + 1 NC fault signal
3 NO

metering typeAverage current Iavg
Phase current I1, I2, I3 RMS
Temperature
Earth-fault current
Imbalance current

measurement accuracy5...15 % earth fault current internal measurement (for current > 0.1 A)
1 % voltage (100...830 V)
3 % power factor (cos φ > 0.6)
5 % earth fault current external measurement (< 5 % or 0.01 A)
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power

overvoltage categoryIII
connection pitch5.08 mm
connections - terminalsControl circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end

tightening torqueControl circuit: 0.5…0.6 N.m flat screwdriver 3 mm
pollution degree3
electromagnetic compatibilityElectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5

width91 mm
height61 mm
depth122.5 mm
net weight0.53 kg
web servicesWeb server
compatibility codeLTMR
Environment
standardsEN 60947-4-1
CSA C22.2 No 14
IEC 60947-4-1
UL 508
IACS E10

product certificationsATEX
C-Tick
EAC
LROS (Lloyds register of shipping)
NOM
BV
RINA
KERI
ABS
UL
CSA
DNV
RMRoS
GL
CCC

protective treatment12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068

fire resistance650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94

ambient air temperature for operation-20…60 °C
ambient air temperature for storage-40…80 °C
operating altitude<= 2000 m without derating
mechanical robustnessVibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27

IP degree of protectionIP20
Offer Sustainability
Sustainable offer statusGreen Premium product
REACh RegulationREACh Declaration
EU RoHS DirectiveCompliant
EU RoHS Declaration

Mercury freeYes
RoHS exemption informationYes
China RoHS RegulationChina RoHS declaration 
Product out of China RoHS scope. Substance declaration for your information

Environmental DisclosureProduct Environmental Profile
Circularity ProfileEnd of Life Information




LTMR08CBD_副本

Copyright © 2019 Sunup (Wuhan) Industrial Equipment Co., Ltd. All Right Reserved.


Sunup (Wuhan) Industrial Equipment Co., Ltd is not an authorized reseller, agent or affiliate of any brand or manufacturer. All trademarks, brand names and logos whose products are sold on the website are used for identification purposes only and are registered trademarks of their respective owners, all rights reserved. The use of a trademark, brand name or product on our website does not imply that the company trademark or brand belongs to or endorses our website. All products are 100% original, genuine and legally purchased from authorized sources.