Brand New Schneider LTMR08MFM Motor controller very competitive price and One year Warranty

- Product description
- Contact us
Brand New Schneider LTMR08MFM Motor controller very competitive price and One year Warranty
range | TeSys | |
---|---|---|
product name | TeSys T | |
device short name | LTMR | |
product or component type | Motor controller | |
device application | Equipment monitoring and control | |
measurement current | 0.4…8 A | |
[Us] rated supply voltage | 100...240 V AC 50/60 Hz | |
current consumption | 8...62.8 mA | |
supply voltage limits | 93.5…264 V AC | |
communication port protocol | Modbus | |
bus type | Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, RJ45 with 2 shielded twisted pairs Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, terminal block with 2 shielded twisted pairs |
[Ui] rated insulation voltage | 690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508 | |
---|---|---|
[Uimp] rated impulse withstand voltage | 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 | |
short-circuit withstand | 100 kA conforming to EN/IEC 60947-4-1 | |
associated fuse rating | 4 A gG for output 0.5 A gG for control circuit | |
protection type | Reverse polarity protection Locked rotor Earth-leakage protection Thermal overload protection Phase failure Overload Thermal protection Power factor variation Load fluctuation Phase unbalance Overload (long time) | |
network and machine diagnosis type | Event recording Fault recording Waiting time after overload tripping Running hours counter/operating time Phase fault and earth fault trip counters Trip context information Starting current and time Motor control command recording Remaining operating time before overload tripping Trip history information | |
logic input number | 6 | |
input current | 3.1 mA at 100 V 7.5 mA at 240 V | |
current state 0 guaranteed | Logic input: 0...40 V and <= 15 mA for 25 ms | |
current state 1 guaranteed | Logic input: 79...264 V and >= 2 mA for 25 ms | |
maximum output switching frequency | 2 Hz | |
load current | 5 A at 250 V AC for logic output 5 A at 30 V DC for logic output | |
permissible power | 480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) | |
maximum operating rate | 1800 cyc/h | |
contacts type and composition | 1 NO + 1 NC fault signal 3 NO | |
metering type | Average current Iavg Temperature Earth-fault current Imbalance current Phase current I1, I2, I3 RMS |